Aqua DET 1 Instrukcja obsługi - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Pompa wodna Aqua DET 1. Aqua DET 1 20 stron.

Aqua DET 1 Instrukcja obsługi
ENGLISH
The AQUA DET 1 pump is designed to dispense dishwashing chemicals. The pump has its own electronic
circuit board that controls all the injections of products that are delivered to the dishwashing machine via 2
peristaltic pumps. The flow of each pump can be changed from ~10 to 100% by rotating 2 internal trimmers
that vary the rate of rotation of the motor. AQUA DET 1 is fitted with 2 peristaltic pumps mounted on a
polypropylene box.
 Power supply: Multi-tension 24VAC-230VAC 50/60Hz
 Detergente flow-rate: ~0 ... 4 l/h
 Rinse flow-rate: ~0 ... 1 l/h
 IP protection. IP65
 Weight: 1.6 kg
 Dimensions: L240 H235 P135
MATERIALS IN CONTACT WITH THE CHEMICALS
Hose of the pump head
Hose of the pump head
Suction hose
Detergent Delivery hose
Rinse Delivery hose
Foot Filter
Detergent Injection nipple
Rinse Injection nipple
Our pumps are built according to the actual general directives endowed with CE mark in conformity with the
following European directives:
n° 2004/108/CE " e s.m.i.
n° 2006/95/CE "DBT Low Voltage Directive" e s.m.i.
n° 2011/65/UE , 2012/19/UE "direttive RoHs e WEEE" e s.m.i.
The operating principle of a peristaltic pump is based on the pressure against a soft tube mounted into a
housing. The pump consists of a rotor which is fitted with rollers on its ends which compresses the tube. As
the fluid travels along the tube, the fluid sucked in, is ejected into the delivery line. This process is then
repeated by the next arm of the rotor. The flow depends on the speed of rotation of the motor and on the
diameter of the tube. By unscrewing the central knob on the front panel of the pump it is possible to remove
the transparent cover and gain access to the tube.
 Twin pump AQUA DET1
 Detergent Injection fitting in Polypropylene
 Rinse Injection fitting in Stainless Steel
 2 x foot filter
 2 mt PE 4x6 hose for Rinse Delivery
 6 mt PVC 4x6 hose for Detergent, Rinse Suction and Detergent Delivery
 Fixing screws for wall mounting
Detergent pump (SX pump)
Connect the PVC 4x6 hose (internal diameter 4 mm, external 6 mm) to the suction nipple (1).
Insert the foot filter to the other end of the hose.
Connect the PVC 4x6 hose (internal diameter 4 mm, external 6 mm) to the delivery nipple (1).
Insert the PP Detergent Injection fitting to the other end of the hose.
Tighten nuts (3 and 4) (see Fig.2).
ADSP7000430
07/05/2015
TECHNICAL FEATURES
Santoprene®
Silicone (upon request Tygon®)
PVC
PVC
PE
Polypropylene
Polypropylene
Stainless Steel
DESIGN STANDARD
OPERATING PRINCIPLE
WHAT'S IN THE BOX
HYDRAULIC INSTALLATION (Fig. 2)
rev. 2.4
5/20