Aqua 9+ AQ9-200GPD Instrukcja instalacji - Strona 8
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla System wodny Aqua 9+ AQ9-200GPD. Aqua 9+ AQ9-200GPD 13 stron. Natural ionic calcium alkaline water system
Installation Manual ::
Aqua 9+ Natural Ionic Calcium Water System
BEFORE YOU START
Ensure there is a pressure regulator installed and is in proper working order before pro-
ceeding. Inlet water pressure should be subject to between 40 to75 PSI. You should
contact a licensed plumber if you are not able to check this on your own .
Excessive pressure could cause damage to the system and water could leak out.
Failure to follow proper installation instructions voids all warranties and liabilities.
The system should be installed where it is protected from freezing. Do not install the
system where it would cause damage if failure or leakage occurred.
1. Prior to installation the feed water assembly, please assure that the following water
conditions are met.
Feed water conditions
Inlet pressure
Temp
pH Level
TDS Level
2. All local plumbing codes should be followed
3. Locate cold water supply , drain placement and faucet placement.
4. Locate water system and storage tank placement. ( Should allow yourself room for
easy access to future filter changes)
5. Contact a plumber if you are not familiar with standard plumbing codes , procedures
or are not able to handle the installation.
6. Verify there is a working pressure regulator in place with a maximum of 75 PSI. If
pressure exceeds PSI mentioned above make sure to contact a licensed plumber for
assistance.
Min.
Max.
40 PSI
75 PSI
40 deg F
100 deg F
2
2000 ppm
8
11