ELECTRICAL CONNECTIONS
• Field connections must comply with national and local codes, i.e. CSA C22.1 or
NFPA70. The work must be done by a qualified electrician.
• Heater must be permanently grounded and bonded.
Bonding will drastically reduce the chances of electrolysis, "Electrical Corrosion."
• Use copper conductors only.
• Disconnect all power sources before performing any work on unit.
• Standard Power Supply: 230Volts – 60Hertz – 1Phase.
• See unit data plate for specific ampacity.
Wiring Main Power Supply
1. Remove the screws from lower left and right side of front cover (service panel).
2. Remove the screws on left side of hinged electrical enclosure.
3. Route weather tight, flexible conduit through opening at base of unit.
4. Connect conduit to bottom of the electrical enclosure using a weather tight fitting. A
1.13" hole is provided near the main contactor to accept a weather tight fitting. Mounting
conduit directly to the electrical enclosure will ensure a moisture tight seal, extending the
life of the heater.
5. Attach grounding conductor to the ground lug provided inside the electrical enclosure
(labeled).
6. Install L1 and L2 input conductors to the line side of the main contactor. (See wiring
diagrams.)
7. Connect bond wire (at least #8 solid copper wire) to bond lug provided on right or left
side of coil header plate to pool pump bonding terminal or other suitable location.
Wiring External Controls and Remotes
NOTE: When connecting remotes and external controls to the main control within the electrical
enclosure, conduit must be used within the enclosure to ensure a definite separation of factory
wiring/circuits and external control wiring. When installed ensure that there is no transmission of
stress to main control wire terminal connections.
1. Route conduit through .875" hole provided in bottom of electrical panel.
2. Route conduit to the circuit board.
3. Connect control wiring to either Pool/Spa or Chiller connection at the bottom right of
control board.
4. SEE: REMOTE CONTROLS THERMOSTATS AND CONTROLS