ULTITUBE D5
Flow sensor and special interconnecting cable are optional accessories and not in-
cluded in delivery.
Compatible flow sensors:
Flow sensor with 5.6 mm nozzle (53061)
Flow sensor "high flow" (53068)
Connection cable for flow sensor (53027, 53100)

4.6. Connector "Bus" for aquabus or RGBpx

4.6.
Connector "Bus" for aquabus or RGBpx
4.6.
4.6.
Connector "Bus" for aquabus or RGBpx
Connector "Bus" for aquabus or RGBpx
Depending on configuration, this connector can either be used for communication
with other Aqua Computer devices or to connect RGBpx products (up to 90 ad-
dressable LEDs). Simultaneous use of both functions is not possible!
Compatible aquabus devices:
aquaero 6 XT (53146, 53206, 53250, 53251, 53262, 53263)
aquaero 6 PRO (53145, 53253)
aquaero 6 LT (53234)
aquaero 5 XT (53089, 53125, 53249)
aquaero 5 PRO (53090, 53252)
aquaero 5 LT (53095)
If the RGBpx product to be connected has more than one RGBpx connector, the
connector marked with the word "IN" must be used! Additional RGBpx products
may be connected to the "OUT" connector.
Compatible RGBpx products:
RGBpx LED-Strip (53268, 53269, 53270)
RGBpx lighting set for PC cases (53271)
RGBpx lighting set for monitors (53272)
RGBpx Splitty4 (53267)
RGBpx LED ring of ULTITUBE series reservoirs (34094, 34095, 34096,
34100, 34109, 34110)
RGBpx LED ring for ULTITUBE (34115)
RGBpx LED ring for aqualis 450/880 (53274)
RGBpx LED ring for aqualis 100/150 (53276)
RGBpx LED ring for 60 mm reservoir (53277)
RGBpx cable (53259, 53260, 53261, 53266)

4.7. Technical details D5 NEXT

4.7.
Technical details D5 NEXT
4.7.
4.7.
Technical details D5 NEXT
Technical details D5 NEXT
Power supply voltage (Vin):
Maximum power consumption: 65 Watts (including fan and RGBpx)
Maximum pump pressure:
Maximum fan output power:
Ambient temperature range:
Coolant temperature:
The pump must not run dry for longer periods of time!
- 6 -
5 V DC ±5 %, 12 V DC ±5 %
370 mbar (approx. 3.7 m water head)
25 Watts
10 to 40 °C (noncondensing)
0 to 50 °C
Aqua Computer GmbH & Co. KG