Aqua Cooler AC-M8WREBFY Instrukcja obsługi i konserwacji - Strona 3

Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla System wodny Aqua Cooler AC-M8WREBFY. Aqua Cooler AC-M8WREBFY 5 stron. Wall-recessed hydration station

INSTALLATION

The installation must be in accordance with AS/NZS 3500.1 and AS/NZS 3500.2, as well as the
instructions below. Pipe jointing and installation is a trade skill and Aqua Cooler recommended
this process is performed by qualified personnel only.
Plumbing rough-in and wall opening should be prepared as shown on Roughing-in drawing. This
drinking water cooler is designed to be operated at a water supply line pressure of up to 100
psi (690 kPa). A pressure regulator must be installed in front of the unit's water inlet if the water
pressure (including any possible pressure spikes) could exceed 100 psi (690 kPa).
Insert frame assembly into wall opening and secure to studs. NOTE: FRONT FLANGE OF
FRAME(S) MUST BE FLUSH WITH THE FINISHED WALL SURFACE.
Models with cooling unit, attach cradle mounting angles to unit mounting cradle with 4 screws
provided. Slide unit mounting cradle into frame and secure in place with 4 screws, provided.
(Cradle is used only when cooling unit is to be installed.) NOTE: BOTTOM FLANGE ON CRADLE
IS TO BE BEHIND FRAME FRONT FLANGE.
Slide cooling unit onto cradle.
It is recommended that flexible conduit be used to supply power to cooling unit (and when
applicable to electronic bottle filler electrical box in frame). Check electric current available. Type
and voltage must be the same as listed on unit data plate. This drinking water cooler is intended
to be connected to a 20A minimum ground fault circuit interrupting (GFCI) device to meet UL
requirements.
Install provided waste tee to bottle filler tailpiece.
Install the fountain mounting plate to the frame assembly using provided screws.
Prior installing upper panel assembly with electronic bottle filler: This is a good time to change
units from gallons (default setting) to liters, if preferred, when program is set as FILTERED unit,
slide switch on back of circuit board to side marked "Liter". To ease access to the remote toggle
button for programming once the panel assembly and fountain is installed, feed the remote
toggle button through the fountain mounting plate noted in step 6h. After unit is completely
assembled, refer to the "Set-Up Guide for Oasis® Hands-Free Bottle Filler Electronics" item
number 030099-482 to change program settings.
Place upper panel(s) in place on frame top angle and fasten with 2 flat head screws, provided, at
the bottom.
Remove bottom plate(s) from fountain arm(s). Save the screws.
Snap reveal gasket(s) over back end(s) of fountain arm(s).
Add compression connector(s), furnished by others, to fountain waste tube(s) and slide back
approximately 3" out of way. Use a 3/8 compression fitting for water line connections, provided
by others. An internal strainer is provided for water line connection. For dielectric isolation of
fountain(s) a non-metallic water line connection can be used.
Hang fountain(s) on mounting plate studs. NOTE: AS THE FOUNTAIN IS HUNG, FEED THE
WASTE TUBE INTO THE WASTE STUB ON THE WALL SIDE.
Your Partner in Cool.
4
INSTALLATION CONT.
Tighten fountain(s) to mounting plate(s) with the 5/16-18 nuts and washers and the 1/4-20 bolts
and washers provided.
Complete plumbing to fountain(s) and bottle filler. Tighten waste connection(s) and then connect
water supply line(s) with the 3/8 compression fitting. When installing split level models, hang
upper fountain first, then connect water tube assembly provided to its water inlet. Hang lower
fountain next and connect the tube to its water inlet supply line. For combination units with
chillers, hang upper unit first and connect chiller tube, provided, containing tee to fountain water
inlet tube with compression fitting, provided, and then to chiller unit water out fitting. Hang lower
unit next and connect long connecting tube, provided, to tee and then to fountain with other
compression fitting.
Where applicable, secure bottom panel(s) top edge(s) behind frame middle cross member(s) and
fasten panel(s) at bottom to frame with flat head screws, provided.
Slide reveal gasket(s) back into notch between panel and arm. The gasket serves as an appearance
item only (to close up any opening around panel and mounting plate).
Check plumbing connection for leaks. On new plumbing installations, run water through the
bubbler(s) until water taste is satisfactory. Adjust regulator to achieve desired stream height. Add
bottom plate(s) back to fountain arm(s).

MAINTENANCE

The only maintenance required is the removal of dirt and lint from the condenser. Inspection
should be made at 3 mount intervals. Remove the grille and clean the condenser with a vacuum
attachment.
Outside of unit can be wiped clean with mild soap and water mixture. Never use harsh chemicals
or abrasive cleaners, including any chlorine solutions. Rinse thoroughly with clean water, then dry
surfaces.

OVERLOAD PROTECTION

The compressor motor, where used, is equipped with an automatic reset protector which will
disconnect the motor from the line in case of an overload.
LUBRICATION
TThis unit is equipped with a hermetically sealed compressor and requires no additional
lubrication. The fan motor, where used, on this unit seldom needs oiling, but if required, a few
drops of SAE 10 oil should be used.
5