INSTALLATION CONT.
Complete the installation by turning on the water source and checking for leaks.
Ensure nothing is obstructing the fan blade. Plug the power cord back into the wall outlet and
then test to ensure the bottle filler is functioning properly.
Once the unit has been verified to be functioning properly, install the front cover panel by
inserting the top flanch up between the wrapper and center bracket, then tipping the panel back
to the fountain. Secure it with the 2x #8 hex screws at the base of the unit.
Complete the installation by installing the Bottle Filler top and filter Access Panels.
Your Partner in Cool.
12
SET-UP GUIDES
BOTTLE FILLER ELECTRONICS:
Factory default program settings:
• Units: Gallons
• Unfiltered unit
• Flow meter = Rate selected
• Filter capacity = 1250 gallons (4731L)
• Bottle count = 0.5L (1 bottle)
• Flow rate = 1.2 GPM
• 20s max dispense time.
For each model top cap will need to be set aside until programming is complete. Remove top
cap by unscrewing two (2) T15 torx screws if needed. Remove wire tie bundling pushbutton
inside bottle filler and feed it through hole in cooler top. You can then adjust program using
pushbutton through access panel of cooler.
To change the program settings, follow these steps:
DISPLAY
ACTION
000000000 BOTTLES
Depress button for 3 seconds to enter into the following menu settings and make changes.
REUSED
Note: at anytime it will exit menu and save settings when idle for 10 seconds (no button press) and
(Home Screen)
revert back to Home Screen.
LTR/GAL
Depress button for 3 seconds to change from Gallons to Litres, or momentary press to advance to
GAL
next menu.
UNFILT/FILT?
Depress button for 3 seconds to change from Unfiltered to Filtered unit, or momentary press to
UNFILT UNIT
advance to next menu
FLOW METER?
Depress button for 3 seconds to change from Rate Selected to (Flow) Meter Enabled, or
RATE SELECTED
momentary press to advance to next menu
SELECT RATE
To change flow rate, momentarily depress button to change whole gallon digit.
1.2 GPM UNIT
Hold button 3 seconds to advance to TENTHS of gallon digit.
Depress momentarily to change the digit.
Hold button 3 seconds to advance to the next menu.
RESET 000000000
Depress button for 3 seconds to reset Gallon or Litre count, or momentary press to advance to
GALLON CNT
next menu
[LTR COUNT]
FILT CAPAC
Depress button for 3 seconds to change filter capacity to 3000 GAL [11355 Litres] for Versafiller I
OF 1250 GAL
or Galaxi green filter, or momentary press to advance to next menu
[4731 LTR]
3 sec rule?
Depress button for 3 seconds to switch from 0.5L bottle to 3 sec rule, or momentary press to
0.5L
advance to next menu. (The 3 Sec rule increases the bottle count based on a 3 second dispense.)
RESET 00000000
Depress button for 3 seconds to reset (Home Screen) BOTTLES REUSED count, or momentary
BOT COUNT?
press to advance to next menu.
Bot Filler
Depress button for 3 seconds to change maximum dispense time to 10, 20, or 30 seconds, or
Set_time:20s
momentary press advance to next menu.
RUN CAL
Depress button for 3 seconds to run calibration again, or momentary press to advance to next
AGAIN?
menu.

REMOVING FROM SERVICE

• Close water shut off valve and disconnect power to the CHILLER.
• Provide container to catch water to be drained and place under the cold tank drain.
• Remove the drain plug from the drain tube.
• Actuate the bottle filler and allow the water to drain into the bucket. Replace drain plug.
• Disconnect power to the BOTTLE FILLER.
• Disconnect the water supply line at the shut off valve.