Symptom
Erratic display
Manual overtemp
Tripping Frequently
6
Part # 8533-066-001 2/10
Probable Cause
Initial Start-up
Grounding
Program
Voltage spike
Recirculating
chamber Lint
Accumulation
Exhaust ducting
Excessive lint buildup
Clean linto of of top
heat air chamber
above tumbler
Suggested Remedy
If erratic on initial start-up, leave power on for
approximately one hour and check machine
operation again.
Machine must be grounded by separate conductor
back to neutral bar in breaker box.
Check program and make corrections if
necessary.
Power down machine for 20 seconds and
repower. If no improvement, replace control.
Remove manual overtemp thermostat and inspect
in chamber for excessive lint build up. Access also
gained to this chamber by removing recirculation
duct mounted at bottom of chamber, or the panel
inside burner chamber between burners and rear
back panel
Remove exhaust duct at rear of dryer and inspect
for excessive lint build up in complete duct from
dryer to where duct exits building.
Remove front panel completely. Be careful of any
wiring attached. Remove heated air chamber
cover and clean above tumbler back to burner
housing.