A.H. Systems SAS-510-2 Instrukcja obsługi - Strona 7
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Antena A.H. Systems SAS-510-2. A.H. Systems SAS-510-2 14 stron. Log periodic antenna
A.H. Systems SAS-510-2 Log Periodic Antenna
EMISSIONS TESTING MEASUREMENT POINT:
For 3 and 10 meter testing, the measurement is made from the center of the
antenna radiating elements and is annotated by a measurement point sticker
(per ANSI C63.5).
IMMUNITY TESTING MEASUREMENT POINT:
Measurement is made from the tip of the antenna and typically preformed at a 1
meter distance. (3 meters per IEC 61000-4-3)
© A.H. Systems inc. – January 2007
REV B
7