Fencee power DUO PD70 Instrukcja obsługi - Strona 16

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Zasilanie Fencee power DUO PD70. Fencee power DUO PD70 20 stron.

Do not connect battery or accumulator energizers to electric power network or devices being
connected to network voltage, except for sources determined to that by the manufacturer, in
any case. This energizer may not be used by persons (including children) who have limited physi-
cal, perceptive or mental abilities or do not possess sufficient experiences and knowledge, when
they are not under supervision or are not trained for operating energizer by persons who are
responsible for their safety. Children should be under supervision so that there is not chance that
they play with the energizer.
Ensure that all connected network supplied auxiliary circuits have at least the same protection
class as energizer.

11. TROUBLESHOOTING

In case that electric fence system does not give pulse or voltage is lower than 3 kV and red
diode is blinking on BARGRAPH indicator, it is necessary to check below listed causes
Cause
Energizer does not work?
Red LED light is blinking
Red LED light is blinking and warning siren
sounds (beeping)
No LED signal is burning
Lead-in or short circuit of supply lines of the
fence system
Conductor has adverse properties (thin
diameter, high resistance)
Low-quality earthing, too short earth rod,
corrosion, dry soil
Lead-in via growth near fence system
Conductor on ground (for example break,
insufficient mechanical tension)
Too long fence system. Was correct
accessories used for given purpose?
Insulator pierces, losses occur
Conductor is connected via knot, insufficient
connection
16
Fault removal
Disconnect the device from the fence system and switch
it on again! If blue or violet LED is burning and yellow
or green LED is flashing on BARGRAPH indicator, then
the device works properly. Otherwise, the device is
damaged (contact your salesman). When using battery
and accumulator devices, observe correct wiring of poles.
Battery voltage decreased below 12 V - replace the battery
with a sufficiently charged one or connect adapter.
Battery voltage decreased below 11,6 V - replace the
battery with a sufficiently charged one or connect adapter.
Energizer is switched off manually or battery voltage
decreased below 11,4 V and energizer was switched off
automatically. Reason is protection of battery from its
deep discharge (and battery destruction). Replace the
battery with a sufficiently charged one or connect adapter
– until battery voltage reaches at least 12 V, red LED will
be burning.
Do not use conventional cables for supply lines. High-
voltage cable is recommended.
Use high-quality conductor with low resistance and
larger diameter. Ensure high-quality correct connection
of conductors.
Add next rod, moisten.
Remove the growth (mow it).
Repair fencing, use special connectors, stretch conductor.
Use accessories suitable for given length of fence system
and for animals – in case of need, consult specialized
salesman.
Replace defective and weather-worn insulators.
Use relevant special connectors for the conductor.