AQUA FILTER EXCITO Instrukcja instalacji - Strona 11

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Systemy filtracji wody AQUA FILTER EXCITO. AQUA FILTER EXCITO 14 stron.

Remove elbow from used AIPRO-20MS cartridge and
connect it with replacement cartridge AIPRO-20MS. Repeat
this action to replace remaining cartridges.
IMPORTANT NOTE! During cartridge installation,
remember to follow proper direction of water flow
indicated by an arrow on cartridge label.
5
Connect the elbows: one with the water inlet of the first
cartridge; one with the water outlet of the last cartridge.
12.2. Filter cartridge replacement – System equipped with cartridges with regular connectors
Disconnect tubing from elbow inlet connector attached to
cartridge AIPRO-20MS.
Disconnect tubing from elbow outlet connector attached to
cartridge AICRO-L4.
Proceed as follows:
1) remove safety clips
2) Symmetrically press quick connector's collar
3) Pull out the tubing
NOTE! Described procedure can be found on page 4,
point 6.2.
NOTE! When pulling out the tubing, use caution to
prevent the tubing from damage. Collapsing of the
tubing may result in damage and future water leaks.
Insert all replaced cartridges into mounting clips of the
system's housing. Make sure that AIPRO-20MS is first from
the left.
IMPORTANT NOTE! During cartridge installation,
remember to follow proper direction of water flow
indicated by an arrow on cartridge label.
IMPORTANT NOTE! Before the first use and after each
cartridge replacement procedure, the system should be
flushed with 15 liters of water. Next, allow the system to
standby for 5 - 6 hours to activate the filtration media.
After these procedures, the water is ready for
consumption.
To replacement hollow fiber membrane follow the above
described procedure.
Remove all filter cartridges out of mounting clips and the
system housing.