Coyote C1PB Instrukcja instalacji - Strona 2

Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Palnik Coyote C1PB. Coyote C1PB 2 stron.

C1PB
Install Notes:
 Combustible material can not be within 24" of the grills frame
 This applies to all directions - horizontal & vertical
 Shaded area above on "TOP VIEW" illustrates the 24" minimum requirement (not to scale for rendering purposes)
 The grill is designed to hang from the counter top with no support underneath
Ventilation Requirements:
 Regardless if you are using a combustible or non-combustible building material, you must include at least two vents within the island.
 These vents must be at least 20 sq. in. each and allow fresh air to move from the grill cabinet to the exterior environment.
 For a propane setup, the vents should be installed lower as propane is heavier than air.
 For a natural gas setup, the vents should be located higher in the island, as natural gas is lighter than air.
 Do not locate the two vents on the same wall of the island. Cross ventilation is key to allow any excess heat or trapped gas to dissipate.
Important Note to Installer:
and consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your built-in side burner.
INSTALL GUIDE
NON-COMBUSTIBLE CONSTRUCTION ONLY
Insulated Jacket NOT Required
24"
21"
CUTOUT WIDTH
24"
INCLUDING
COUNTERTOP
CUTOUT WIDTH
10 1 /4"
OPENING
HEIGHT
DOORS / DRAWERS
OPENING WIDTH
This file is not intended to replace your Owners' Manual which contains specific safety requirements
www.coyoteoutdoor.com
3 /4"
SIDE
BURNER
OPENING
TOP VIEW
COUNTERTOP
OVERHANG
4"
21"
24"
21"
4"
1 1 /2" MIN
4"
OPENING
HEIGHT
FRONT VIEW