Mounting Junction Box on a DIN Rail
Mount the MobileView Junction Box within an enclosure using a DIN rail.
To install the Junction Box on a DIN rail:
1. Mount the DIN rail.
2. Hook the top slot over the DIN rail.
3. While pressing the Junction Box against the rail, snap the Junction Box into
position.
To remove your Junction Box from the DIN rail:
1. Place a screwdriver in the DIN rail latch at the bottom of the Junction Box.
2. Holding the Junction Box, pry downward on the latch until the Junction Box is
released from the DIN rail.