Deye SUN-5K-SG01LP1-EU Instrukcja naprawy - Strona 2
Przeglądaj online lub pobierz pdf Instrukcja naprawy dla Falownik Deye SUN-5K-SG01LP1-EU. Deye SUN-5K-SG01LP1-EU 17 stron. 5kw storage inverter
5KW Storage Inverter Repairing Guide
Error
F-01
Description
Turn off AC switch and DC switch, and check the PV panel DC input polarity.
Positive
Negative
Error
F-02
Description
The impedance between DC+ and ground or DC – and ground is too low, turn off the
AC switch and DC switch, and then check whether the PV panel (aluminum frame) is
grounded well and inverter is grounded well. Open the cover of inverter and then check
the inside ground cable is fixed well on the shell.
Error
F-03
Description
DC input polarity Reverse Fault
DC insulation impedance permanent fault
DC leakage current fault