Actuator Assembly
4. Carefully insert the stem (B35) into the housing assembly (B1) with the teeth facing the gear
sector (B2) position.
5. Apply a paint-like coating of lubricant to the teeth and bearing hubs of the gear sector (B2) and
to the teeth of the stem (B35) using one of these lubricants:
- Keystone Zeniplex-1 (recommended)
- Amoco Amolith Grease #1-EP (alternate)
- Amsoil GHD (alternate)
- Mobil Mobilux EP 1 (alternate)
- Shell Alvania EP 1 (alternate)
- Texaco Multifak EP 1 (alternate)
Note: Do not get grease on the bearing surfaces of the stem or on the three stem bearings.
6. Note that the stem (B35) has one tooth with a punch mark, and the gear sector (B2) has two
pair of teeth with punch marks. The one marked tooth in the stem must mesh between the pair
of marked teeth that will provide 90º of gear sector rotation as the stem moves in the direction of
the air stroke. The spring-to-close and spring-to-open configurations are shown in Figure 1.
Accordingly, place the gear sector in position in the housing assembly (B1).
7. Mount the cover (B4) and gasket (B22) to the housing assembly (B1) with the four cover screws
(B36). Tighten the screws to 26 ± 3 foot pounds (35 ± 4 Nm).
8. Mount the pointer (B6) to the gear sector (B2) with the four screws (B7). Tighten the screws to
18 ± 2 inch pounds (2.0 ± 0.2 Nm).
9. Place the diaphragm (B14) in position on the lower diaphragm cover (B12). Align the holes in
the diaphragm with the holes in the cover.
10. Place the diaphragm cover (B11) in position on the diaphragm. Align the holes in the cover with
the holes in the diaphragm and in the lower diaphragm cover.
11. Assemble the cover screws (B15), nuts (B16) and washers (B42) in the holes, and tighten all
the screws evenly until the diaphragm is in contact with both covers. Then tighten the screws in
a crisscross pattern to 12 ± 2 foot pounds (16 ± 3 Nm) for the Model 145, or to 18 ± 2 foot
pounds (24 ± 3 Nm) for the Model 250.
September 2015
DeZURIK MODELS 145 AND 250 DIAPHRAGM ACTUATOR ISO MOUNTING
(continued)
Page 9
DeZURIK
D10368