Przeglądaj online lub pobierz pdf Instrukcja dla Kontroler DeZurik G16. DeZurik G16 19 stron. Cylinder operated actuator used on pec eccentric valves
Disassembling Actuator
When eccentric valves are mounted in a vertical pipeline, or mounted in a horizontal pipeline with the
plug stem horizontal, gravity can cause the plug to swing to a lower position in the valve body when the
actuator is removed. To avoid this problem, place the plug in the lowest position before removing the
actuator.
1. Discontinue flow and relieve pipeline pressure.
Accidental operation of power actuator can cause personal injury or equipment damage.
Disconnect and lock out power to actuator before servicing.
2. Disconnect and lock out the pneumatic power to prevent accidental operation of the actuator.
Disconnect the tubing from the cylinder.
3. Remove the extension cap from the actuator housing. On units with booster cylinders, carefully
remove the booster cylinder or cylinders.
4. Place the actuator in the open position, then shut off cylinder supply pressure and disconnect
the tubing.
5. Remove the nuts and washers from the end of the rack rod.
6. Remove the screws or nuts fastening the cylinder assembly to the housing and carefully remove
the cylinder assembly by sliding it away from the actuator until the rack rod clears the actuator
housing.
7. If the valve is 4–20" (100–500mm):
a. Remove lock nut, spring washers, wrenching nut & pointer from the plug stud.
b. Proceed to step 9.
8. If the valve is 24–36" (600–900mm):
a. Loosen lockscrews #1 about 6 to 8 turns and loosen lockscrews #2 about 3 turns. See
Figure 4.
b. Using a soft hammer, tap the heads of the #1 lockscrews to loosen the keys.
9. Remove the four screws holding the wrenching nut to the gear sector, then remove the stud
locknut, spring washers and the wrenching nut with the keys attached.
10. Scribe corresponding lines on the actuator cover
and housing, then remove the cover screws and
cover from the top of the actuator.
11. Mark the teeth of the rack and gear as shown in
Figure 6 and lift the gear sector out of the actuator.
12. Remove the rack from the housing.
August 2012
Cylinder Operated G-Series Actuator
Page 13
DeZURIK
Figure 6 – Scribe Marks
D10022