Aqua Lung PARA SWIMMER VEST Podręcznik użytkownika - Strona 2
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Sprzęt bezpieczeństwa Aqua Lung PARA SWIMMER VEST. Aqua Lung PARA SWIMMER VEST 2 stron.
PRE-OP CHECK OUT
Prior to each use, the vest should be given a thorough visual inspection
and function test.
1. Fully inflate the vest and set aside for 30 minutes; loss of firmness indicates
leakage, which must be corrected before use.
2. Ensure that all stitched together components are not separating.
3. Check that the oral inflation tube and valve properly functions by depressing
the valve and blowing into the tube. Ensure the knurl nut on the oral inflation
tube turns freely.
4. Remove the CO
cartridges and inspect both actuators. Ensure both ac-
2
tuators operate correctly by pulling the knob to operate the actuating lever
and checking that the piercing pin travels up and down. Return the actuat-
ing lever to the firing position prior to re-threading the CO
the actuator.
NOTE:
Ensure the actuator is free of debris and the CO
washer is in place prior to re-installing the CO
5. Perform a function check on the over pres-
sure relief valve (OPRV) by fully inflating the
vest and then squeezing the vest to ensure
the OPRV opens allowing air to escape.
Next, pull the knob and cord assembly to
ensure the dump valve is correctly working
by allowing air to escape (See Fig. 3).
NOTE:
The over pressure relief valve (OPRV) will actuate when the
pressure inside the vest exceeds 1 - 2 PSI (0.07 - 0.24 BAR) greater
than external pressure.
FOLDING THE VEST
Prior to each use, the vest should be placed in its proper configuration.
1. Ensure vest is clean and dry. Lay flat and
deflate the vest.
2. Fold lower edge up until the bottom edge
of the bottle wrap is visible underneath.
(See Fig. 4).
cartridge into
2
cartridge
2
cartridge.
2
Figure 3
Figure 4
3. Fold each side in and overlap them until
CO
cartridges are visible on each side.
2
(See Fig. 5).
4. Secure the bottle wrap around the vest by
laying the left flap over the right flap and
securing the hook and loop tape together
tightly (See Fig. 6).
NOTE:
Use of the optional HABD
pocket is possible only if the PSV is
not folded.
POST-OP MAINTENANCE
Proper maintenance will provide for years of reliable service. The Para
Swimmer Vest should be stored away from direct sunlight.
1. After each use, soak the exterior of the
vest with fresh water.
2. Detach HABD/SEA pocket (optional)
and fresh water rinse all components
(See Fig. 7).
3. Open storage pocket and fresh water rinse.
Ensure the hook and loop fabric is clean
from all debris (See Fig. 8).
4. Unscrew both CO
cartridges from the
2
actuators and fresh water rinse all
components.
NOTE:
Remove
CO
cartridge
2
washer from actuator prior to fresh
water rinse.
Figure 5
Figure 6
Figure 7
Figure 8