Calypso First Stage Service Manual
PART #
125712
125716
103133
103137
APF124563
TEST
Immersion Test
Medium Pressure
MP Variation
Table 4 - Torque Specifications
DESCRIPTION / KEY ITEM #
Piston Cap / 2
Inlet Fitting / 15
MP Port Plug / 10
HP Port Plug / 18
Interstage Hose
Table 5 - Test Bench Specifications
CONDITION
Supply Pressure 2900 - 3000 psi
Supply Pressure 2900 - 3000 psi
Supply Pressure 2900 - 3000 psi
TORQUE
18 ft/lbs
18 ft/lbs
20 in/lbs
20 in/lbs
40 in/lbs
SPECIFICATIONS
No leaks
MP at 130 - 145 psi
After cycling the regulator several times,
the MP should not increase by more than
5 psi in 5 - 15 seconds.