Aqua PRO ECO500 Skrócona instrukcja obsługi - Strona 12

Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Podgrzewacz basenowy Aqua PRO ECO500. Aqua PRO ECO500 12 stron. 50,000 btu heat & cool heat pump pool and spa heater

D. Check bolts, cables and connections regularly.
Trouble shooting for common faults
Faulty
Not starting
There is air outlet
but the heating is
not satisfactory
If the above mentioned faults cannot be solved, please contact the professional and inform model
and detailed faulty condition.
Atten: Please don't disassemble and repair the swimming pool heater by yourself, please leave it to
the professionals.
Failure code
EE 1
EE 2
EE 3
EE 4
PP 1
PP 2
PP 3
PP 4
PP 5
PP 6
PP 7
Reason
Main power is off
Switch off
Burnt out fuse
Circuit breaker drops out
Blocked air inlet
Blocked air outlet
3 minutes time lag protection
Temperature set too low
High pressure protection
Low pressure protection
Low water pressure protection
Over current (3 phase machine)
Pool ( SPA )heater sensor failure
Exhaust sensor failure
Coil pipe sensor failure
Intake pipe sensor failure
Air temp sensor failure
Compressor exhaust overload protection
When the temperature<+32 , auto stop protection not Failure
Solutions
Wait for power to be reinstated
Switch on
Replace it
Switch Circuit Breaker back on
Clean out the stem
Clean out the stem
Please wait
Increase
accordingly
12
temperature
setting