8. Updates and Recovery

The IRX1- device can be update automatically or manually. Usually the system should update
its firmware when needed via updates provided from our FTP website.

8.1 Automatic Update

The IRX1- device is usually automatically updated when needed. The updates are distributed
from our FTP server to the device. All update are tested to ensure high quality and efficiency
in our product. There is no need for external intervention on the device to update it using the
automatic update.

8.2 Manual System Recovery

See the remote troubleshooting section.

9. Remote Troubleshooting

It is possible to access the IRX1 for remote assistance. Also, manual firmware and script up-
dates can be achieved. If the problem is the internet connection, it will not possible to do so.
16
Appendix A – Specifications
A.1 System
Operating frequency selection/Bandwidth
Measurement range
Sensitivity
AGC attenuator
Level accuracy
Maximum input level
Monitoring mode
Frame capture time
Continuous ingress detection capability
Communication port
Communication protocol
Power
Operating temp
Storage temp
A.2 Physical
Dimensions
Weight
Maximum relative
CPAT FLEX (IRX1)
Operation Manual
effigis.com
06.78 MHz: 30 kHz
13.56 MHz: 14 kHz
27.12 MHz: 30 kHz
-24 to 12 dBmV
-24 dBmV (BER < 10^-6) (attenuator @ 0 dB)
0-15 dB in 0.5 dB steps
±2 dB on signal pulses
40 dBmV per RF input (integration in the 5 to 45 MHz
band)
Continuous shared detection between 8 RF ports
10 ms
100 events/sec/IRX1
10/100 Base-T Ethernet
IP (version 4)
120 VAC, 0.7A (60W) fully loaded
0°C – 60°C (32°F – 140°F)
-20°C – 80°C (-4°F – 176°F)
1.75'' x 16.60'' x 18.50'' [H x W x D]
4.5 cm x 42.2 cm x 47.0 cm
4 Kg
humidity 80% for temperatures up to 31°C (88°F)
decreasing linearly to 50% relative humidity at 40°C
(104°F).
17