CPG HP424 Instrukcja instalacji i obsługi - Strona 4
Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Zakresy CPG HP424. CPG HP424 12 stron. Countertop range
Ensure gas supply and gas type, as shown on unit nameplate, agree.
Unit installation must conform with the National Fuel Gas Code, ANSI Z223.1/NFPA 54, the National
Gas Installation Code, CSA-B149.1, or the Propane Installation Code, CSA-B149.2 as applicable and
in accordance with local codes.
Screw legs into the permanently fastened nuts on the four corners of the unit and tighten by hand.
Level the unit by turning the adjustment screw at the bottom of each leg. Do not slide unit with legs
mounted, lift if necessary to move unit.
Pipe threading compound must be resistant to the action of liquefied petroleum gases.
Caution: DO NOT use an open flame to check for leaks. Check all gas piping for leaks with a soap and
water solution before operating unit.
THESE UNITS ARE SUITABLE FOR INSTALLATION ON NON-COMBUSTIBLE SURFACES ONLY.
Combustible clearances:
6" sides (152 mm)
Noncombustible clearances:
0" sides ( 0 mm)
Do not obstruct the flow of combustion and ventilation air under the unit by the legs or behind the
unit by the flue.
Adequate clearance for air openings into the combustion chamber is required. Do not place objects
between the bottom of the unit and the counter top.
There must be adequate clearance for removal of the front panel. All major parts except the burners
are removable thru the front if the gas line is disconnected.
MODEL
WIDTH
IN. (MM)
HP212
12(305)
HP424
24(610)
HP636
36(915)
Note: regulator – 75mm/3.25 inch depth. Dimensions above do not include regulator.
GENERAL INSTALLATION INSTRUCTIONS
6" rear (152 mm)
0" rear ( 0 mm)
4" floor (102 mm)
SPECIFICATIONS AND DIMENSIONS
DEPTH
IN. (MM)
26.8(680)
26.8(680)
26.8(680)
4" floor (102 mm)
HEIGHT
# OF
IN. (MM)
BURNERS
15(380)
2
15(380)
4
15(380)
6
4
BTU/PER
TOTAL
NAT/LP
BTU/ Hr
22,000
44,000
22,000
88,000
22,000
132,000
W.C.
IN.
6/10
6/10
6/10