CPG 351FFOP40L Instrukcja serwisowa - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Fryer CPG 351FFOP40L. CPG 351FFOP40L 13 stron. Open pot fryers
Również dla CPG 351FFOP40L: Podręcznik użytkownika (16 strony)

User Manual
Service Manual
351FFOP40N, 351FFOP50N, 351FFOP40L, 351FFOP50L
351CLCPG15NL, 351CLCPG24NL, 351CLCPG36NL,
351CLCPG48NL, 351CLCPG60NL, 351CLCPG72NL
Manifold pressure check
1.
With Thermostat in "OFF" position and gas
combination valve in the "OFF" position
2.
Remove pressure tap plug from manifold with
7/16" wrench (Fig. 7)
3.
Install fitting for manometer, ensure there
are no gas leaks
4.
With manometer ready, ignite the pilot flame and
turn knob on gas combination valve to the "ON"
position
5.
Turn thermostat temperature knob 'ON' to ignite
burners, ensure oil is covering burner tubes inside
fryer pot
6.
Manometer should read
4" of W. C. for natural gas and
10" of W. C. for propane
7.
Use thread sealing compound or tape when re-
installing plug
8.
Check connections for gas leaks
Adjust manifold pressure, if needed. Ensure
incoming gas pressure matches name plate on unit
1.
Remove cover cap with flat head screwdriver
(Fig. 8)
2.
Use flat head screwdriver to turn adjusting screw
Clockwise = Increase
Counterclockwise = Decrease
3.
Reinstall cover cap when correct pressure has
been reached
www.cookingperformancegroup.com
FIG. 7
FIG. 8
5