CPG 351FGC100DDL Instrukcja serwisowa - Strona 9
Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Piekarnik CPG 351FGC100DDL. CPG 351FGC100DDL 18 stron. Gas powered convection ovens
Również dla CPG 351FGC100DDL: Podręcznik użytkownika (12 strony)
Service Manual
351FGC100(L/N) | 351FGC200(L/N)K
351FGC100DD(L/N) | 351FGC200DD(L/N)K
Surface Igniter
Visually check that surface igniter 'glows' when thermostat first calls for heat. Check with
1.
unit 'ON' and thermostat calling for heat (Fig. 20 & 21).
Check for 120 volts from S2 connection on ignition module to Neutral wire on back of unit
2.
(Fig. 22).
Check for 0.8 - 1.5 amps from S2 connection on ignition module to Neutral wire on back on
3.
unit (Fig. 22).
Disconnect wire terminals, check resistance through igniter, approx. 23 Ohms at 70°F.
4.
Fig. 20
Flame Sensor
Visually check that flame sensor 'glows' when burner flames are 'ON'. Check with unit 'ON',
1.
thermostat calling for heat and burner flames 'ON' (Fig. 25).
Check for 5 VDC on ignition module 'FC' terminals. If less than 2 VDC, replace flame sensor
2.
(Fig. 24).
Fig. 23
www.cookingperformancegroup.com
Fig. 21
Fig. 24
Fig. 22
Fig. 25
9