AVS Electronics VECTOR Plus Instrukcja instalacji - Strona 10
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla System bezpieczeństwa AVS Electronics VECTOR Plus. AVS Electronics VECTOR Plus 12 stron. Bidirectional gsm interface
Dialler programming to send "by command" SMS messages
To make a telephone dialler connected to VECTOR Plus activate SMS messages "by
command", the following steps are required:
1: program one of the telephone numbers of the dialler with the proper digits sequence
as explained hereon.
(0000nnTT)
2: associate to that telephone number some default communication protocol.
3: program the dialler to make one single calling attempt to that telephone number. If there are
repetitions, the SMS message will be sent many times.
4: program an output from the dialler or control panel to activate by a few seconds bringing to
negative "-" the "GSM" input terminal of the interface, while the telephone number is being
dialled.
NOTE 1: using AVS ELECTRONICS diallers or control panels, setting to "0" the number of attempts of
telephone calls will cause the dialler to make one single calling attempt.
NOTE 2: if the telephone number for SMS activation is not the first number "called" by the dialler, once the
"GSM" input terminal of VECTOR Plus has received the pulse to negative, all telephone calls previous to
the SMS activation number will be executed through the GSM channel, while successive ones will occur
over PSTN line.
Example:
Tel. numb 1: alarm telephone call
Tel. numb 2: alarm telephone call
Tel. numb 3: alarm telephone call
Tel. numb 4: SMS activation command
Tel. numb 5: alarm telephone call
Tel. numb 6: alarm telephone call
Call to #1
Call to #2
Call to #3
SMS cmd #4
Call to #5
Call to #6
GSM
x
x
x
x
PSTN line
x
x
10