DGF Fabrications N1 Instrukcja instalacji i konserwacji
Przeglądaj online lub pobierz pdf Instrukcja instalacji i konserwacji dla Kominek wewnętrzny DGF Fabrications N1. DGF Fabrications N1 14 stron. Gas effect fires (natural gas & lpg) for decorative purposes only
SPECIAL DECORATIVE GAS FIRE
INSTALLATION & MAINENANCE INSTRUCTIONS FOR
DGF FABRICATIONS GAS EFFECT FIRES (NATURAL GAS & LPG)
NATURAL GAS MODELS: N1, N2, N3, N4
This fire must be installed by a properly qualified (in accordance with National and Local Regulations)
•
Installation Engineer.
The connection of this appliance, and ventilation requirements (if any) are to be according to National
•
and Local Codes.
The chimney should be swept before the appliance is installed.
•
This appliance is intended for decorative purposes only.
•
Do not throw rubbish on, or attempt to burn any materials on this appliance. Any debris or foreign
•
matter must be removed from the fire.
The appliance should be serviced by a qualified engineer every 12 months.
•
LIGHTING & CONTROLLING THE FIRE – MANUAL FIRE
Switching On/Ignition. Depress the control knob and turn counter clockwise. Gas will flow to the
•
pilot burner, the piezo igniter will give off a high voltage spark and the pilot burner will light. (more than
one attempt may have to be made on first igniting).
Keep the control knob depressed for approximately 10 seconds to heat up the thermocouple.
Turn the control knob fully counter clockwise to release gas to the main burner.
Adjust according as desired.
Control of gas flow. Turning the control knob clockwise reduces the gas rate from the pre-set
•
maximum to the pre-set minimum setting. Turning between maximum and minimum does not actuate
the piezo igniter. The control valve can only be set on pilot by depressing the control knob and turning
it to the pre-selected pilot position.
Switching off. Press the control knob and turn clockwise to off.
•
Units 1-3 Vulcan St, Edward St Industrial Estate, Darlington. DL1 2UL – Tel: 01325 281304; Fax: 01325 481889
FOR DECORATIVE PURPOSES ONLY
LPG MODELS: L1, L2, L3, L4
NOTICE TO INSTALLER
Please make sure that the user has read and understood these
instructions and that Record Data has been completed on page 3.
Please ensure this manual is then left with user in a safe place for the
entire life of the fire.
GENERAL
DGF Fabrications;
1