Dell EMC VxRail E560F Instrukcja obsługi - Strona 25
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Serwer Dell EMC VxRail E560F. Dell EMC VxRail E560F 35 stron. Appliances on poweredge servers
Environmental specifications
NOTE:
For additional information about environmental measurements for specific appliance configurations, see Dell.com/
environmental_datasheets.
Table 28. Temperature specifications
Temperature
Storage
Continuous operation (for altitude less than 950 m or
3117 ft)
Fresh air
Maximum temperature gradient (operating and
storage)
Table 29. Relative humidity specifications
Relative humidity
Storage
Operating
Table 30. Maximum vibration specifications
Maximum vibration
Operating
Storage
Table 31. Maximum shock specifications
Maximum shock
Operating
Storage
Table 32. Maximum altitude specifications
Maximum altitude
Operating
Storage
Specifications
–40°C to 65°C (–40°F to 149°F)
10°C to 35°C (50°F to 95°F) with no direct sunlight on the
equipment.
NOTE:
Maximum of 205 W, 28 core processor is supported in
appliances.
NOTE:
Certain configurations may have ambient temperature
restrictions. For more information see the Ambient temperature
limitations section.
For information about fresh air, see
section.
20°C/h (68°F/h)
Specifications
5% to 95% RH with 33°C (91°F) maximum dew point. Atmosphere
must be non-condensing at all times.
10% to 80% relative humidity with 29°C (84.2°F) maximum dew
point.
Specifications
0.26 G
at 5 Hz to 350 Hz (all operation orientations).
rms
1.88 G
at 10 Hz to 500 Hz for 15 min (all six sides tested).
rms
Specifications
Six consecutively executed shock pulses in the positive and negative x,
y, and z axes of 6 G for up to 11 ms.
Six consecutively executed shock pulses in the positive and negative x,
y, and z axes (one pulse on each side of the appliance) of 71 G for up
to 2 ms.
Specifications
3048 m (10,000 ft)
12,000 m (39,370 ft)
Expanded Operating Temperature
Technical specifications
25