Dell EqualLogic PS6110S Instrukcja obsługi sprzętu - Strona 18

Przeglądaj online lub pobierz pdf Instrukcja obsługi sprzętu dla Serwer Dell EqualLogic PS6110S. Dell EqualLogic PS6110S 50 stron. Equallogic ps series iscsi storage arrays with microsoft windows server failover clusters

Dell EqualLogic PS6110S Instrukcja obsługi sprzętu
1. cluster node 1
2. cluster node 2
3. switch 0
4. switch 1
Cabling The Dell EqualLogic PS4000/PS4100/PS6010/PS6510 Storage Arrays
1.
Connect a network cable from the network switch 0 to Ethernet 0 on the control module 1.
2.
Connect a network cable from the network switch 0 to Ethernet 0 on the control module 0.
3.
Connect a network cable from the network switch 1 to Ethernet 1 on the control module 1.
4.
Connect a network cable from the network switch 1 to Ethernet 1 on the control module 0.
5.
Repeat steps 1 to 4 to connect the additional Dell EqualLogic PS4000/PS4100/PS6010/PS6510 storage array(s) to the
iSCSI switches.
NOTE: For PS4100 storage array, having all 4 cables in steps 1 through 4 provides highest level of cable
redundancy. It works fine with only 2 cables. You can skip either step 1 or 2, and either step 3 or 4.
For more information, see the figures below.
Figure 9. Cabling an iSCSI SAN-Attached Cluster to a Dell EqualLogic PS4000 Storage Array
1. cluster node 1
2. cluster node 2
3. switch 0
4. switch 1
18
5. Dell EqualLogic PS6110 storage system
6. control module 0
7. control module 1
5. Dell EqualLogic PS4000 storage system
6. control module 1
7. control module 0