Dell Force10 S25 Series Podręcznik konfiguracji
Setting Up Layer 2 Switching
Step
Task
1
Select all ports.
This example assumes that the stack ID is 0.
The prompt changes to:
Force10(conf-if-range-gi-0/1-24)#
2
Enable the selected ports for Layer 2 switching.
3
Set the maximum Link MTU (frame size) to handle
Jumbo frames.
4
Administratively enable all ports.
5
Return to CONFIGURATION mode.
6
Repeat the above sequence for the 10GbE ports.
7
After physically connecting the ports, use the
ip interfaces brief
administrative status (the Status field in the output)
and link status (the Protocol field).
The following screenshot illustrates the use of these commands (use a space before and after the hyphen):
Force10(config)#interface range gigabitethernet 0/1 - 24
Force10(conf-if-range-gi-0/1-48)#switchport
Force10(conf-if-range-gi-0/1-48)#mtu 9252
Force10(conf-if-range-gi-0/1-48)#no shutdown
21:22:23: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed interface Admin state to up: Gi 0/1
21:22:23: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed interface Admin state to up: Gi 0/2
21:22:23: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed interface Admin state to up: Gi 0/3
21:22:23: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed interface Admin state to up: Gi 0/4
21:22:23: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed interface Admin state to up: Gi 0/5
21:22:23: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed interface Admin state to up: Gi 0/6
21:22:23: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed interface Admin state to up: Gi 0/7
21:22:23: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed interface Admin state to up: Gi 0/8
21:22:23: %STKUNIT0-M:CP %IFMGR-5-ASTATE_UP: Changed interface Admin state to up: Gi 0/9
! ----------------------- output truncated ------------- !
Force10#show ip interface brief
Interface
GigabitEthernet 0/0
GigabitEthernet 0/1
GigabitEthernet 0/2
GigabitEthernet 0/3
GigabitEthernet 0/4
GigabitEthernet 0/5
GigabitEthernet 0/6
GigabitEthernet 0/7
GigabitEthernet 0/8
GigabitEthernet 0/9
! ----------------------- output truncated ------------- !
4
show
command to inspect
IP-Address
unassigned
unassigned
unassigned
unassigned
unassigned
unassigned
unassigned
unassigned
unassigned
unassigned
Basic Layer 2 Setup and Buffer Tuning of the S25P for Storage Environments
Command Syntax
interface range gi 0/1 - 24
(A space is required before and
after the dash in the command.)
switchport
mtu 9252
no shutdown
exit
interface range te 0/25 - 28
do show ip interfaces brief
OK
Method Status
NO
Manual up
NO
Manual up
NO
Manual up
NO
Manual up
NO
Manual up
NO
Manual up
NO
Manual up
NO
Manual up
NO
Manual up
NO
Manual up
Command Mode
CONFIGURATION
INTERFACE RANGE
INTERFACE RANGE
INTERFACE RANGE
INTERFACE RANGE
CONFIGURATION
INTERFACE RANGE
Protocol
down
down
down
down
down
down
down
down
down