Dell PowerEdge 2300 Instrukcja aktualizacji - Strona 13

Przeglądaj online lub pobierz pdf Instrukcja aktualizacji dla Serwer Dell PowerEdge 2300. Dell PowerEdge 2300 24 stron. Vga card installation instructions
Również dla Dell PowerEdge 2300: Instrukcja konfiguracji (2 strony), Szybki start i połączenia (5 strony), Instrukcja aktualizacji (23 strony), Instrukcja instalacji stojaka (26 strony), Instrukcje instalacji (1 strony)

Dell PowerEdge 2300 Instrukcja aktualizacji
support.dell.com
1.
Remove the system board mounting tray as follows.
a.
Unlock and remove the computer cover.
For instructions, see the Installation and Troubleshooting Guide.
b.
To access the system board, release the system-board tray latch at the back
lower corner of the tray (see Figure 1-2) and pull the tray open to the first
stop position (or service position).
NOTE: From the service position, if you depress and release the tray latch and
pull the tray out again, you will come to a second stop position that is used by
manufacturing. To remove the tray completely from any position, depress and
hold the latch, and pull the tray out of the chassis.
c.
Record the location of any internal expansion card cables, record the slot
number assignments, and then remove all the expansion cards.
Place the expansion cards in antistatic bags or on a grounded antistatic mat
or other antistatic surface.
d.
Record the locations and disconnect all internal cables attached to the sys-
tem board.
e.
Press and hold the tray release latch as you slide the system board and
mounting tray assembly completely out of the chassis.
f.
Lay the tray assembly with the system board facing up on a flat surface.
g.
Remove the mounting screw from the mounting tray.
h.
Slide the system board 6.3 mm (0.25 inch) toward the front (left edge of the
mounting tray, as shown in Figure 1-3) and lift the system board away from
the mounting tray.
2.
To install the upgrade mounting tray assembly (provided in your upgrade kit) in
your PowerEdge 4300 system, perform the preceding steps in reverse order.
3.
Remove the microprocessors.
See "Removing the Microprocessors", found later in this document.
Dell PowerEdge Systems — Microprocessor Upgrade
1-9