Dell PowerEdge 650 Instrukcja wymiany - Strona 7
Przeglądaj online lub pobierz pdf Instrukcja wymiany dla Serwer Dell PowerEdge 650. Dell PowerEdge 650 16 stron. Replacing the system and backplane board assemblies
14
Replace the cooling shrouds.
15
Install the memory modules, if they were removed. See "System Memory" in your Installation
and Troubleshooting Guide.
16
Connect the control panel cable to the front of the backplane. See "Installing the Control
Panel Assembly" in your Installation and Troubleshooting Guide.
17
Connect the hard-drive interface cables either to the backplane or through the backplane to
the hard-drive controller card, if one is installed.
18
Connect the hard-drives power cables from backplane connectors JP1 and JP2 to the hard
drives. See "Installing a Hard Drive" in your Installation and Troubleshooting Guide.
19
Connect the CD/diskette drive interface cable to the backplane connector CN1.
20
Install the power supply. See "Replacing the Power Supply" in your Installation and
Troubleshooting Guide.
21
Connect the power supply cable to the back of the backplane (connector J2). See "Replacing
the Power Supply" in your Installation and Troubleshooting Guide.
22
Install the fan assemblies. See "Installing a Fan Assembly " in your Installation and
Troubleshooting Guide.
23
Close the system. See "Closing the System" in your Installation and Troubleshooting Guide.
24
Reconnect the system to its electrical outlet and turn the system on, including any attached
peripherals.
Replacing the System and Backplane Board Assemblies
7