Dell PowerEdge C6105 Podręcznik techniczny - Strona 27

Przeglądaj online lub pobierz pdf Podręcznik techniczny dla Serwer Dell PowerEdge C6105. Dell PowerEdge C6105 36 stron. Rack server
Również dla Dell PowerEdge C6105: Instrukcja obsługi (46 strony), Podręcznik portfolio (27 strony)

Dell PowerEdge C6105 Podręcznik techniczny

Power supplies

The base redundant system consists of two hot-plug power supplies in a 1+1 configuration available
at 1100W and 1400W. Dell PSUs have achieved Platinum efficiency levels as shown in Table 15.
Form factor
Output
1400W AC
Redundant 86 mm
1100W AC

System power supply throttling feature

The PowerEdge C6105 supports a power supply throttling feature that protects the system if power
consumption exceeds the maximum for the supply (either 1400W or 1100W). In configurations
where power consumption is greater than the maximum, redundancy is lost, and the PowerEdge
C6105 throttles power consumption of the two or four independent nodes to stay within the power
budget. Performance is degraded in this mode, but the system continues to operate. After you
replace the failed power supply, redundancy is restored and all nodes resume normal operation.
27
Dell PowerEdge C6105 Rack Server Technical Guide
Table 15.
Power supply efficiency
Class
Platinum+
Gold
Efficiency targets by load
10%
20%
89.0%
93.0%
N/A
88.0%
50%
100%
94.5%
92.0%
92.0%
88.0%