Dell PowerEdge FX2 Podręcznik konfiguracji - Strona 4

Przeglądaj online lub pobierz pdf Podręcznik konfiguracji dla Serwer Dell PowerEdge FX2. Dell PowerEdge FX2 24 stron. Upgrading from 10gbe pass-through modules to fn410s i/o modules
Również dla Dell PowerEdge FX2: Pierwsze kroki (2 strony), Rozpoczęcie pracy z systemem (2 strony)

Dell PowerEdge FX2 Podręcznik konfiguracji
1

Introduction

This deployment guide covers a step-by-step procedure to minimize network downtime when upgrading from
Dell 10 Gigabit Ethernet (10GbE) Pass-through Modules (PTMs) to PowerEdge FN410S Input/Output
Modules (IOMs) in a PowerEdge FX2 chassis.
When upgrading, all servers in the chassis may remain up throughout the process. In the scenario covered in
this guide, the PTMs are hot-swapped one at a time so that no more than half of the server network ports are
down at any point in the upgrade.
Upgrading from PTMs to FN410S IOMs provides the following benefits:
Adds multilayer switching capability to the chassis
Adds redundancy to links going to the top-of-rack (ToR) switch
Optimizes east-west traffic by allowing server-to-server communication within the chassis
Can significantly reduce cabling at the back of the chassis
Additional configuration is not required on the FN410S for many common deployments
Note: If FX2 server network adapters are configured such that a single LACP NIC team spans both PTMs,
and therefore will span both FN410S IOMs upon replacement, the FN410S IOMs will need to be configured
as Virtual Link Trunking (VLT) peers. This will bring all network ports in the FX2 chassis down during
configuration. Use the
1.1

Typographical conventions

This document uses the following typographical conventions:
Monospace text
Bold monospace text
Underlined monospace text
Italic monospace text
1.2

Before upgrading

Dell EMC recommends reviewing the
before upgrading to FN410S IOMs. The Easy Deployment Guide covers basic FN IOM tasks such as the
following:
Resetting to factory defaults
Establishing a remote or serial connection to the management interface
Disabling and re-enabling Uplink Failure Detection (UFD)
4
PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules | version 1.0
PowerEdge FX2 – FN I/O Module – VLT Deployment Guide
CLI examples
Commands entered at the CLI prompt
CLI examples that word wrap (text is entered as a single command)
Variables in CLI examples
Dell PowerEdge FN I/O Module (FN IOM) - Easy Deployment Guide
for this scenario.