AT-CV10x Series Converteon Line Cards
Installation Guide
Overview
The AT-CV10x Series (AT-CV101, AT-CV102, and AT-CV102/x Series) line cards feature
a 10Base-TX twisted pair port and a 100Base-FX fiber optic port. You can install these
line cards in any Converteon Series chassis. The line card features one fiber optic port
and one copper twisted pair port. Both ports feature half- or full-duplex mode operation.
The line cards are hot-swappable into and out of a Converteon chassis.
Related Documents
For details on the features and functions of a Converteon chassis, refer to the relevant
documents on our web site, www.alliedtelesis.com.
Verifying Package Contents
Ensure that the following items are included in your package:
One AT-CV10x Series line card
This installation guide
If any item is missing or damaged, contact your Allied Telesis sales representative for
assistance.
AT-CV10x Series Line Card Components
An AT-CV10x Series line card has the components shown below. The AT-CV102 line card
is shown as an example.
3 K
SW2 DIP Switch Set
3 K
AT -C
Fiber Optic Port LEDs
V1 0
2
LK AT
T
Fiber Optic Port
X
M
M
R
X
Twisted Pair Port LEDs
LK
AT
10/100-TX Twisted Pair Port
T
X
RDY
Line Card Status LEDs
SML
ML
555
Port Descriptions
Fiber Optic Port
The fiber optic port on the AT-CV10x Series line card is IEEE 802.3ah-compliant. The
connectors and operating distance vary depending upon the model:
AT-CV101: multi-mode fiber ST connector and a maximum operating distance of 2km
(1.24 miles)
AT-CV102: multi-mode fiber SC connector and a maximum operating distance of 2km
(1.24 miles)
AT-CV102/1: single mode fiber SC connector with a maximum operating distance of
15km (9.32 miles)
AT-CV102/2: single mode fiber SC connector with a maximum operating distance of
40km (24.85 miles)
Twisted Pair Port
The 10/100Base-TX compliant twisted pair port has an RJ-45 connector and a maximum
operating distance of 100 meters (328 feet). Category 5 (5E), 100 Ohm shielded or
unshielded twisted pair cabling is required. The pinouts for this port are shown in
"Twisted Pair Port Pinouts."
LEDs
An AT-CV10x Series line card as three status LEDs, two LEDS for the fiber optic port, and
three LEDs for the twisted pair port, as described in "LED Descriptions."
DIP Switches
Two sets of DIP switches allow you to set the operating mode and MDI/MDI-X features, as
described in "DIP Switch Settings."
Installing an AT-CV10x Series Line Card
Note
Before you install an AT-CV10x Series line card, refer to the appropriate Converteon
chassis installation guide for electrical safety and emissions information.
Warning: Remove all metal jewelry, such as rings and watches, before installing
or removing a line card from a powered-on chassis.
Caution: Be sure to observe all standard electrostatic (ESD) precautions, such as
wearing an antistatic wrist strap, to avoid damaging the device. A line card can be
damaged by static electricity
SW1 DIP Switch Set
Note
You can install a Converteon line card in any Converteon chassis line card slot.
To install an AT-CV10x Series line card, perform the following procedure:
1.
Remove the AT-CV10x Series line card from its shipping package and store the
package in a safe place. You must use the original package if you need to return the
3K
3K
unit to Allied Telesis.
2.
Configure the line card's DIP switches as required. Refer to "DIP Switch Settings" for
more information.
3.
Select any line card slot in the chassis where you want to install the AT-CV10x
Series line card, and remove the blank slot cover if one is installed.
4.
Align the back edge of the line card with the to and bottom alignment guides located
inside the slot.
5.
Slide the line card into the slot until the front of the card is flush with the front of the
chassis.
Note
Avoid touching the line card components.
6.
Secure the AT-CV10x Series line card to the chassis by using a Phillips screwdriver
to tighten the captive screw on the faceplate.
1
Note
Always tighten the captive screw to secure the line card to the chassis.
7.
Repeat this procedure to install additional AT-CV10x Series line cards.
LED Descriptions
Status LEDs
The line card has three status LEDs as described in the following table. For more
information about Smart MissingLink and MissingLink, refer to the relevant management
software user's guide.
LED
State
RDY
Green
The line card has passed diagnostics.
Off
The line card has not passed diagnostics.
SML
Green
The Smart MissingLink mode is enabled.
Off
The Smart MissingLink mode is disabled.
ML
Green
The MissingLink mode is enabled.
Off
The MissingLink mode is disabled.
Fiber Optic Port LEDs
The fiber optic port has two LEDs, as described in the following table. For more
information about Smart MissingLink, refer to the relevant management software user's
guide.
LED
State
LK
Green
A link has been established on the port.
Blinking
While in Smart MissingLink mode, a valid connection is established
Green
on the port while a link on the other port is lost.
Off
No link has been established on the port.
AT
Blinking
TX/RX activity has been detected on the port.
Green
Off
There is no TX/RX activity on the port.
Twisted Pair Port LEDs
The twisted pair port has three LEDs, as described in the following table. For more
information about Smart MissingLink, refer to the relevant management software user's
guide.
LED
State
LK
Green
A link has been established on the port.
Blinking
While in Smart MissingLink mode, a valid connection is established
Green
on the port while a link on the other port is lost.
Off
No link has been established on the port.
AT
Blinking
TX/RX activity has been detected on the port.
Green
Off
There is no TX/RX activity on the port.
FD
Green
(AT-CV102 only) The port is operating in full-duplex mode.
Off
The port is operating in half-duplex mode.
2
Description
Description
Description
3