Dell EqualLogic PS Series Instrukcja obsługi sprzętu - Strona 12
Przeglądaj online lub pobierz pdf Instrukcja obsługi sprzętu dla Przechowywanie Dell EqualLogic PS Series. Dell EqualLogic PS Series 48 stron. Storage arrays
Również dla Dell EqualLogic PS Series: Konfiguracja (2 strony), Instrukcja obsługi sprzętu (50 strony), Konserwacja sprzętu (46 strony)
PS6210 Hardware Owner's Manual
Shutting Down and Restarting an Array
A PS Series array includes redundant, hot-swappable drives, power supplies, and control modules (in
a dual control module array). You can remove a redundant component without affecting operation if a
functioning component is available. Otherwise, Dell recommends that you cleanly shut down the array
and turn off power before removing a component.
When an array is shut down, any volumes with data on the array will be set offline until the array is
successfully restarted. Being offline affects initiators that are connected to the volumes.
Array shutdown procedure
1. Connect to the array in one of the following ways:
•
Use telnet or SSH to connect to a functioning IP address assigned to a network interface on
the array. Do not connect to the group IP address.
•
Use the null modem cable, shipped with the array, to connect the serial port on the active
control module (ACT LED is green) to a console or a computer running a terminal emulator.
Make sure the serial line characteristics are as follows:
•
9600 baud
•
One STOP bit
•
No parity
•
8 data bits
•
No flow control
2. Log in to an account with read-write access, such as the
3. Enter the
shutdown
login: grpadmin
Password:
Welcome to Group Manager
Copyright 2001-2013 Dell Inc.
group1> shutdown
If you are using a serial connection to shut down an array, it is safe to turn off power when the "press
any key" message appears. (Pressing any key will restart both control modules.)
If you are using a network connection, the session will be disconnected before the array is fully shut
down. Confirm that the ACT LED on each control module is off (not lit) before turning off power to
the array.
After performing array maintenance, you can turn on power to the array. When the array restart
completes, the member and volumes will be set online.
6
command, as follows:
1 Basic Storage Array Information
account.
grpadmin