Dell PowerVault MD3400 Instrukcja obsługi - Strona 45
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przechowywanie Dell PowerVault MD3400. Dell PowerVault MD3400 47 stron. Storage arrays
Również dla Dell PowerVault MD3400: Podręcznik dla początkujących (8 strony), Podręcznik wdrażania (27 strony)
Environmental
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
Airborne contaminant level
Class
5% to 95% at a maximum wet bulb temperature of 33
°C (91 °F)
0.26 G
at 5 Hz to 350 Hz in operational orientation
rms
1.88 G
at 10 Hz to 500 Hz for 15 minutes (all six
rms
sides tested)
One shock pulse in the positive z axis of the system at
31 G for 2.6 ms in the operational orientation
Six consecutively executed shock pulses in the positive
and negative x, y, and z axes (one pulse on each side of
the system) at 71 G for up to 2 ms
Maximum 3000 m (9842.5 ft)
NOTE: For altitudes above 2950 ft, the maximum
operating temperature is derated 1.8 ºF/1000 ft.
Maximum 12192 m ( 40,000 ft)
G1 as defined by ISA-S71.04-1985
45