together, the switch allows the host server to see only devices included in that zone, decreasing the
amount of time it would otherwise take for the host server to query attached, but out-of-zone, devices.

Switch Zoning Guidelines

The storage array imposes specific requirements that must be followed when setting up Fibre Channel
switch zoning:
If a Fibre Channel switch is used to connect your host server and storage array, it must be zoned. Un-
zoned or open switches cannot be used.
WWN port zoning is recommended. While hard zoning (zoning by device ID) is supported, LUN
masking uses the WWN identifier. You can mix WWN and hard-zoned ports in the same zone.
Multi-port HBAs are supported. Each port in a multiple-port HBA represents one initiator. Each
initiator must be connected to a single logical switch zone.
No more than four paths (port-to-port segments) can be established from a single, physical host
server(s) to a single RAID controller.
A zone can contain multiple targets and span multiple storage arrays (single initiator can point to
multiple targets).
NOTE: To simplify troubleshooting, you can assign a single initiator and single target to a zone.
If the Remote Replication premium feature is activated, a separate zone for each replication port is
required. Only data traffic related to Remote Replication can move through that zone. For more
details and requirements regarding Remote Replication, see the Dell PowerVault MD Series Storage
Arrays Administrator's Guide at dell.com/powervaultmanuals.

Setting Up Zoning On The Fibre Channel Switch Hardware

Setting up zoning on Fibre Channel switches varies greatly between manufacturers. For detailed
information on how to set up zoning on your switch, see the manufacturer's product documentation or
technical support website.

Cabling The Storage Array

Cabling the storage array depends on a number of factors such as:
Required level of redundancy or throughput
Number of host servers connected to the storage array
Type of HBAs (dual- or single-port) used in the host server(s)
Remote Replication premium feature (if applicable)
The cabling diagrams shown here do not represent every supported cabling scenario but the concepts of
redundancy and switch logic can be used to build your own configuration.

Redundant And Non-Redundant Cabling

Non-redundant cabling configurations provide a single data path from host server(s) to the storage array.
This type of configuration is only recommended for non-critical data storage. A path failure from a failed
or removed cable, failed HBA, or failed or removed RAID controller module results in loss of host access
to the storage array.
Redundant configurations establish separate data paths between the host server(s) and storage array.
Each path is connected to separate RAID controller modules in the storage array. Redundancy protects
12