Dell PowerVault MD3800f series Instrukcja obsługi - Strona 40

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przechowywanie Dell PowerVault MD3800f series. Dell PowerVault MD3800f series 47 stron. Storage arrays
Również dla Dell PowerVault MD3800f series: Podręcznik wdrażania (34 strony), Podręcznik dla początkujących (8 strony)

Dell PowerVault MD3800f series Instrukcja obsługi
3.
Turn off the host server, storage array, and expansion enclosures.
4.
Reseat the RAID controller module and reconnect cables on the storage array and the host server.
5.
Turn on the expansion arrays and then the storage array and wait until the system is fully booted.
6.
Turn on the host server.
7.
Check the LEDs of all cabled ports. Replace the fibre optic cables of any port(s) where both LEDs are
unlit.
8.
Reboot the host server.
NOTE: You must turn off the host server before resetting the cables on the storage array or
expansion enclosure.
If the problem is not resolved, see

Troubleshooting a Wet System

CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1.
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2.
Open the system.
3.
Disassemble components from the system:
Hard drives
Hard-drive backplane
USB memory key
Cooling shroud
Expansion-card risers (if present)
Expansion cards
Power supply(s)
Cooling-fan assembly (if present)
Cooling fans
Processor(s) and heat sink(s)
Memory modules
4.
Let the system dry thoroughly for at least 24 hours.
5.
Reinstall the components you removed in step 3.
6.
Close the system.
7.
Turn on the system and attached peripherals.
If the system does not start properly, see
8.
If the system starts properly, shut down the system and reinstall all of the expansion cards that you
removed.
9.
Run the appropriate diagnostic test. For more information, see Using System Diagnostics.
If the tests fail, see
Getting
40
Getting
Help.
Getting
Help.
Help.