PS6000 Hardware Maintenance
Table 1-2: Operations Panel Descriptions (Continued)
Item
Status
Off
Flashing orange One or more of the following has occurred:
Warning
condition
LED
Off
Flashing orange One or more of the following has occurred:
Critical error
condition
LED
1–4
Description
No power or normal condition.
•
RAID set is degraded but still functioning.
•
RAID set (volume level) has lost blocks.
•
Component temperature is near a limit.
•
Fan failed or fan RPMs exceed limit.
•
Power supply is not installed or has no power.
•
Cache battery has less than 72 hours of charge.
•
Only one control module installed or control
module has failed over.
•
Control module has insufficient RAM.
•
Syncing active and secondary control modules.
•
No communication between control modules.
•
Installed spare disk does not have enough capacity
to replace a disk in a RAID set.
•
A non-critical hardware component failed.
•
Real-time clock battery is low.
No power or normal condition.
•
RAID is not functioning.
•
Lost block table is full.
•
Temperature exceeds upper or lower limit.
•
Control module cache has lost data.
•
A cooling module is not installed.
•
Both fans on a cooling module have failed.
•
Cache battery temperature is too high to charge
battery.
•
NVRAM coin cell battery failed.
•
Cache contains data that does not belong to any of
the installed disks.
•
More than one valid RAID set exists in array.
•
Control modules are different models.
•
A critical hardware component has failed.
•
Operations panel failed or not installed.
•
Storage enclosure processor that monitors array
components has experienced a failure.