Dell Storage MD1400 series Instrukcja obsługi - Strona 9
Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przechowywanie Dell Storage MD1400 series. Dell Storage MD1400 series 37 stron. Storage enclosure
Również dla Dell Storage MD1400 series: Podręcznik dla początkujących (7 strony), Podręcznik administratora (48 strony)
NOTE: At least one EMM must be installed in the enclosure. If only one EMM is installed in the
enclosure, it must be installed in the primary EMM bay and a blank must be installed in the
secondary EMM bay. See
Figure 5. Enclosure Management Module
Item
Indicator,
Button, or
Connector
1,2,3,4
SAS port (Input or
Output)
5
USB Mini-B (serial
debug port)
6
7-Segment
Display
Enclosure failover when two EMMs are installed
If two EMMs are installed, a certain degree of failover is offered. Control and monitoring of the enclosure
elements can be transferred from one EMM to another in the event of an EMM failure. A failover occurs
whenever network communication is ended between an EMM and its peer.
In the event of a peer EMM failure, the surviving EMM activates the amber status LED of the failed EMM.
The surviving EMM then takes over the responsibility of enclosure management, which includes
monitoring and control of the enclosure LEDs, power supply units, and fans.
EMM thermal shutdown
If critical internal temperatures are reached, the enclosure turns off automatically through either a
thermal shutdown command issued by the EMM firmware or through a command from Dell
OpenManage Server Administrator.
Installing an EMM blank
Icon
Description
Provides SAS connections for cabling the host or an upchain
expansion enclosure and to the next down chain expansion
enclosure in a daisy chain.(Single Port, Redundant, and Multi-
chain Configuration)
For engineering use only.
Display the enclosure location in SAS Chain.
.
9