Dell poweredge VRTX Podręcznik techniczny - Strona 7
Przeglądaj online lub pobierz pdf Podręcznik techniczny dla Przełącznik Dell poweredge VRTX. Dell poweredge VRTX 45 stron. Server
Również dla Dell poweredge VRTX: Podręcznik dla początkujących (30 strony), Podręcznik użytkownika (35 strony), Uwaga dotycząca wydania (5 strony), Podręcznik dla początkujących (14 strony), Skrócona instrukcja obsługi (2 strony), Pierwsze kroki (2 strony)
Fresh Air cooling
Failsafe hypervisors
Specifications
Table 2 lists the technical specifications for the PowerEdge VRTX platform. For the latest information
on supported features, visit Dell.com/PowerEdge.
Feature
Form factor
Server node options
Storage
Power supplies
Cooling
Input devices
7
PowerEdge VRTX Technical Guide
Dell has tested and validated an integrated data center solution that enables you
to operate at higher temperatures or even chiller-less.
The internal dual SD module enables Dell's unique failsafe virtualization
architecture, ensuring uptime by providing failover capability for embedded
hypervisors, such as VMware
®
2012 with Hyper-V
.
Table 2.
Technical specifications
Technical specification
5U rackable tower chassis
Tower configuration:
H: 48.4 cm (19.1 in) with system feet
W: 31.0 cm (12.2 in) with system feet opened
D: 73.0 cm (28.7 in)
Weight (empty) = 31.7 kg (69.7 lb)
Weight (maximum) = 74.8 kg (164.9 lb)
Rack configuration:
H: 21.9 cm (8.6 in)
W: 48.2 cm (19.0 in)
D: 73.0 cm (28.7 in)
Weight (empty) = 24.7kg (54.5 lb)
Weight (maximum) = 68.7kg (151.5 lb)
Up to 4 hot-plug, serviceable Dell PowerEdge M620 and M520
Shared PERC8
Redundant power supply units
110/220V auto-sensing
Redundant power supplies support 2+2 (AC redundancy), and 3+1, 2+1 and
1+1 (power supply redundancy) modes
VRTX comes standard with six hot-pluggable, redundant fan modules and 4
blower modules
Based on Dell Energy Smart Technologies, VRTX fans and blowers are a
breakthrough in power and cooling efficiency
The fans and blowers deliver low-power consumption, but also use next-
generation fan technologies to ensure the lowest possible amount of fresh air
is consumed to cool the enclosure
Front control panel with interactive graphical LCD
—
Supports initial configuration wizard
—
Local server blade, enclosure, and module information and
troubleshooting
Two USB keyboard/mouse connections and one video connection for local
front "crash cart" console connections
®
®
vSphere
ESXi™ and Microsoft
®
®
Windows Server