Dell S4048T-ON Podręcznik dla początkujących - Strona 33
Przeglądaj online lub pobierz pdf Podręcznik dla początkujących dla Przełącznik Dell S4048T-ON. Dell S4048T-ON 35 stron.
Parameter
Storage temperature
Storage and nonoperating humidity
Maximum thermal output
Maximum operational altitude
Maximum nonoperational altitude
Shock
Table 4. AC power requirements
Parameter
Power Supply
Maximum current draw per system
Maximum Power Consumption
Typical Power Consumption
Table 5. DC power requirements
Parameter
Minimum/maximum input voltage range
Input power at full load
Input current at full load
Specifications
–40° to 158°F (–40° to 70°C).
5 to 95 percent (RH), noncondensing.
1568 BTH/hr.
10,000 feet (3,048 meters).
No performance degradation to 35,000 feet
(10,668 meters).
Meets Bellcore Zone 4 earthquake
requirements (MIL-STD-810).
Specifications
100–240 VAC 50/60 Hz.
4.6 A @ 460 watts/100vac.
2.3 A @ 460 watts/200vac.
460 Watts.
338 Watts.
Specifications
-40.5V/ -48V/ -60V
−40.5V/970W −48V/930W −60V/ 950W
(without fan).
−40.5V/980W −48V/940W −60V/ 960W
(with fan).
−40.5V/23.8A −48V/19.0A −60V/ 15.6A
(without fan).
Technical specifications
33