Dell S4248FB-ON Instrukcja konfiguracji - Strona 9

Przeglądaj online lub pobierz pdf Instrukcja konfiguracji dla Przełącznik Dell S4248FB-ON. Dell S4248FB-ON 29 stron. S4200-on series
Również dla Dell S4248FB-ON: Instrukcja instalacji (47 strony)

Dell S4248FB-ON Instrukcja konfiguracji

Fans and airflow

Fan installation is done as part of the factory install based on stock keeping unit (SKU) type.
The S5048F-ON switch has SKUs that support the following configurations:
AC fan unit with fan airflow from the I/O to the PSU—normal
AC fan unit with fan airflow from the PSU to the I/O—reverse
DC fan unit with airflow from the I/O to the PSU—normal
DC fan unit with fan airflow from the PSU to the I/O—reverse
Be sure to order the fans suitable to support your site's ventilation. Use a single type of
airflow fan in your switch. Do not mix reverse and normal airflows in a single switch.
For proper ventilation, position the switch in an equipment rack or cabinet with a minimum of
5 inches (12.7 cm) of clearance around the exhaust vents. The fan speed varies based on
internal temperature monitoring. The switch never intentionally turns off the fans.
Power
To connect the switch to the applicable power source, use the appropriate power cable. An
AC power cable is included with the switch.
When installing AC or DC switches, follow the requirements of the National Electrical Code
ANSI/NFPA 70, where applicable.
The switch is powered-up when the power cable is connected between the switch and the
power source.
CAUTION:
Always disconnect the power cable before you service the power supply
slots. The switch has multiple power cords. Before servicing, ensure that all power
cords are disconnected.
CAUTION:
On the AC switch, use the power supply cable as the main disconnect
device. Ensure that the socket-outlet is located/installed near the equipment and is
easily accessible.
NOTE:
Module power is software controlled. You do not see module LEDs when the
switch powers up in ONIE.
Site preparations
9