Periodic Maintenance
EW-4200D
CHANGING THE OIL
For best engine life, the oil should be changed every 75 to 100
hours, or annually, which ever occurs first.
The unit comes with a dipstick type oil pump for changing the
oil. Start and run the engine for several minutes to get the oil
warm. Stop the engine and remove the Dipstick. Insert the oil
Dipstick Pump tube as deep into the engine as possible. Suck the
oil out using the pump, and dispose of it according to EPA
regulations.
Dipstick Oil Pump
Remove the oil Fill Cap and add one quart of approved oil.
Replace the oil Fill Cap and Dipstick. Start the engine and let it
run for one to two minutes. Stop the engine and check the level
on the oil Dipstick. Adjust the level as necessary.
With practice, the amount of old oil removed will be just the
right amount, so that adding one quart of new oil will bring the
level up to the correct level.
Dipstick
Oil Fill Cap
Although there is an oil Drain Plug on the engine (3/15), it is too
low on the generator to provide easy access for draining.
Installation of an adapter at this location for drain pumps, etc.
will automatically void the warranty.
Drain Plug – DO NOT USE!
AIR CLEANER
The Air Cleaner housing contains a dry element filter. Remove it
and shake the accumulated dirt from it each time you change the
oil. The element should be replaced every 250 to 300 hours.
Air Cleaner Element
Entec West, Inc.
15
16710 SW 72nd • Portland, Oregon 97224 • (503) 624-7118