Non-standard voltages:
OS 440
1. Standard voltage (as supplied)
Electrical connection must be in accordance with local and
national regulations.
Plug and socket connection in accordance with IEC/EN
60309 and IEC/EN 60947 recommended to facilitate
electrical safety tests.
If the machine is connected via a fixed connection, a multi-
pole switch must be provided on site to ensure complete
isolation. Switches with a contact opening of more than 3 mm
should be used. Such switches are, e.g., LS switches, fuses
and contactors (IEC/EN 60947).
A wall socket or mains isolator must be visible and accessible
after installation.
A new connection, modification of an existing installation or
earth checking, including the determination of suitable fuse
rating, may only be carried out by a suitably qualified
electrician in accordance with all local and national
regulations.
Cold water
Min. flow pressure
(soft water)
Max. pressure
Max. throughput
On-site connection thread according to DIN 44 991
Length of connection hose
(parts supplied: 1 connection hose)
Water requirements (average for 60°C programme)
With standard connection (with hot water)
If hot water supply is not available, a sufficient supply of cold
water must be ensured.
If connected to an alternative water supply (optional), subtract
cold water volume.
Hot water
Max. temperature
(soft water)
Min. flow pressure
Max. pressure
Max. throughput
On-site connection thread according to DIN 44 991
Length of connection hose
(parts supplied: 1 connection hose)
Water requirements (average for 60°C programme)
It is possible to connect the machine to a very hot water
supply with temperature from 70°C to max. 85°C. For this a
special connection hose is required. This special hose is
available from the Miele Spares Dept.
In addition, the Miele Service Dept. or an authorised dealer
must reprogram the machine accordingly.
If a hot water supply is not available, connect the hot water
hose to a cold water supply!
Alternative water
Min. flow pressure
supply
Max. pressure
(Optional)
Max. throughput
On-site connection thread according to DIN 44 991
Length of connection hose
(parts supplied: 1 connection hose)
Water requirements (average for 60°C programme)
Technisches Datenblatt / Technical datasheet: PW 6080 EL AV/LP
Datum / Date: 28.10.2009
Frequency
Rated load
Fuse rating
Connection cable cross-sectional area
Connection cable length
Connection cable without plug
(supplied as standard)
V
3 AC 440
Hz
60
kW
7.9
A
3 × 16
mm²
4 × 1.5
mm
2000
kPa
100
kPa
1000
l/min
11
Inch
¾" external thread
mm
1550
l/h
Approx. 70
°C
70
kPa
100
kPa
1000
l/min
11
Inch
¾" external thread
mm
1550
l/h
Approx. 70
kPa
100
kPa
1000
l/min
11
Inch
¾" external thread
mm
1550
l/h
Not yet available
Seite / Page: 9