The electrical connection may only be made to an electrical
system listed in accordance with the national laws, ordin-
ances and directives as well as the local provisions. In
addition to this, the regulations of the power supply utility,
the accident prevention regulations and the insurance com-
pany applicable at the site of installation as well as the
recognized standards of technology must also be observed.
The installation must be performed by a qualified person
(electrician).
The appliance can be connected either via permanent
connections or via plug connections according to IEC
60309-1. Wall receptacles or mains separation devices
must be accessible after the appliance is installed.
However, we recommend connecting the appliance via a
plug connection so that an electrical safety check can be
carried out, e.g. during repair or maintenance.
If it is necessary to install a residual current device (RCD) in
accordance with the local regulations, a residual current
device type B (AC/DC-sensitive) must always be used.
Potential
Externally threaded supports
equalization
for shims and nuts
Accessories such as shims and nuts are only included with
the OS version.
If necessary, equipotential bonding with good galvanic
contact must be created, in compliance with all applicable
local installation specifications.
Peak load switch-
Connected voltage for the control contacts
off
Connection cable, min. cross-section
Connection cable not included.
We recommend making the connection with a flexible con-
nection line and an additional separator. When installed, the
separator should be visible and directly accessible.
Cold water
Water pressure/Min. flow rate
Soft water
Water pressure/Max. flow rate
Max. volume flow
Max. volume flow (in absence of hot and hard water supply)
2 Connector hoses with threaded joint ¾" including Y fitting
(¾" / 1") included with the unit.
Threaded connector fitting at site as per DIN 44 991 (flat
sealing)
Length of connector hose
Average water requirement for a standard program (60°
colored washing) determined at cold, hot and hard water
connection.
If no hot water, add the corresponding water requirement to
the cold water requirement.
If connecting to industrial water (option), subtract that water
requirement from the cold water requirement.
Hot water Soft
Max. water temperature
water
Water pressure/Min. flow rate
Water pressure/Max. flow rate
Max. volume flow
1 Connector hose with threaded joint ¾" included with the
unit.
Threaded connector fitting at site as per DIN 44 991 (flat
sealing)
Length of connector hose
Average water requirement for a standard program (60°
colored washing) determined at cold, hot and hard water
connection.
If no hot water supply, connect hose to cold water!
Technisches Datenblatt / Technical datasheet: PW 6207 EL
Datum / Date: 12-01-2011
3/8" x 1 3/8"
10 × 35 mm
10 M
10 M
AC 230 V
AC 230 V
5 × 1.5 mm²
5 × 1,5 mm²
14.5 psi
100 kPa
145.04 psi
1.000 kPa
5.7 gal/min
26 l/min
9.2 gal/min
42 l/min
1" external
1" external
thread
thread
4‟ 11 1/16"
1,500 mm
30.6 gal/h
approx. 116 l/h
158°F
70 °C
14.5 psi
100 kPa
145.04 psi
1.000 kPa
4.2 gal/min
16 l/min
¾" external
¾" external
thread
thread
4‟ 11 1/16"
1,500 mm
31.4 gal/h
approx. 119 l/h
Seite / Page:
8