G 1xxx/G 2xxx
until the "Start/Stop" LED flashes.
5. Release the Start/Stop button.
6. If the "Start/Stop" LED does not light up, repeat the procedure.
Acknowledgement indicator:
The "Start/Stop" LED flashes slowly (1 flash per second).
Options:
Function
Read the fault memory
Delete fault memory
Component test
Operating hours
LED test
Table 6: Service Mode Summary, G 2020
1.7
Inspira and Diamante - G 2120/G 214x/G 2150
Initial requirements:
1. Close the door.
2. Switch off the appliance.
Accessing:
1. Press and hold the Start/Stop button.
2. Switch on the appliance.
3. Release the Start/Stop button.
Programming
Turn the selector switch to
the 1 o'clock position. While
the "Rinse" LED flashes,
make a note of the fault
code, then press the
Start/Stop button. If the
same fault is shown again,
it means only this one fault
is saved. If a further fault is
shown, press Start/Stop
again. Repeat this
procedure until all faults are
read.
Turn the selector switch to
the 1 o'clock position. Press
and hold Start/Stop until
"Rinse" LED goes out.
Turn the selector switch to
the 3 o'clock position. To
start the component test, or
to access the next
component to be tested,
press Start/Stop.
Turn the selector switch to
the 5 o'clock position. To
check for operating hours,
press Start/Stop.
Turn the selector switch to
the 6 o'clock position. To
start the LED test, press the
Start/Stop button.
9
Technical Information
Display
If the "Rinse" LED is off, no faults
are registered. The flashing rhythm
of the "Rinse" LED indicates which
faults are registered in the fault
memory. (Example: Fault code F14:
The "Rinse" LED flashes 1x slowly
and 4x rapidly at intervals). Fault
code summary, see the service
manual.
If the "Rinse" LED is off, the fault
memory no longer contains any
faults.
The flashing rhythm of the "Rinse"
LED indicates which component
test is activated. For the sequence
of component testing as well as
background information and access
procedure, see the service manual.
The "Rinse" LED's flash pattern
indicates the saved operating
hours: Each slow flash of the
"Rinse" LED corresponds to 1000 h;
each rapid flash, 100 h.
All LEDs light up.