Miele ADVANTA SERIES G 2020 Podręcznik - Strona 3
Przeglądaj online lub pobierz pdf Podręcznik dla Zmywarka Miele ADVANTA SERIES G 2020. Miele ADVANTA SERIES G 2020 14 stron.
G 1xxx/G 2xxx
1
Service Mode
1.1
Inspira and Advanta - G 118x/G 2170/G 218x
Initial requirements:
1. Open the door.
2. Switch off the appliance.
Accessing:
1. Press and hold the Program button.
2. Switch on the appliance.
3. Release the Program button.
4. Immediately press the Program button 3 times; on the 3rd time, hold until
the "Rinse & Hold" LED flashes.
5. Release the Program button.
6. If the "Rinse & Hold" LED does not light up, repeat the procedure.
Acknowledgement indicator:
The "Rinse & Hold" LED flashes slowly (1 flash per second).
Options:
Function
Display and delete fault
memory
Component test
Programming
Press the Program button
1x. If the "SaniWash" LED
displays a fault, check if
further faults were
registered. Press and hold
the Program button until
the "Intake/Drain" LED
lights up. Then briefly
press the Program button.
To delete the fault code
memory, press and hold
the Program button until
the "Intake/Drain" LED
lights up. Then press and
hold the Program button
until the "SaniWash" LED
goes out.
Press the Program button
2x. To start the component
test, press and hold the
Program button until the
"Intake/Drain" LED lights
up. Then briefly press the
Program button.
Repeatedly press the
Program button to
activate the next
component.
3
Technical Information
Display
The "Intake/Drain" LED flashes 1x
rapidly. If faults were registered,
they are indicated by the
"SaniWash" LED. (Example: Fault
code F14: The "SaniWash" LED
flashes 1x slowly and 4x rapidly at
intervals). Fault code summary, see
the service manual. "SaniWash"
LED is off: No faults stored.
The "Intake/Drain" LED flashes 2x
rapidly. The "SaniWash" LED
indicates which component is
currently activated.
Test sequence and background
information, see the service
manual.