Allmatic CT INVERTER AM Instrukcja instalacji - Strona 7
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Jednostka sterująca Allmatic CT INVERTER AM. Allmatic CT INVERTER AM 12 stron. Programmable control board for sliding gates with inverter technology
3.3 Programming menu B (key P2) - List of parameters
The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted; refer to paragraphs dedicated to
each function for more information
MENU B
Manual Motion
End position
Ped. Position
High Speed OP
Low Speed OP
High Speed CL
Low Speed CL
High Torque OP
Low Torque OP
High Torque CL
Low Torque CL
3.4 Programming menu C (key P3) - List of parameters
The following table lists the entries of menu A and reports a short description of the parameters that can be adjusted; refer to paragraphs dedicated to
each function for more information
Language
MENU C
6-1622595
rev.06
13/01/2017
Allows to move the gate at low speed by using the keys located on the control board.
This function is fundamental in order to check the motion during the installation
Learning the full run of the gate, both in opening and in closing
WARNING: this operation must start when the gate is completely closed
Learning of the opening partial run
WARNING: this operation must start when the gate is completely closed
Regulation of the normal speed of the gate during the opening phase
NNN: speed expressed in Hz (frequency of the wave supplied to the motor)
Regulation of the speed of the gate during the opening phase when approaching the end of the run
NNN: speed expressed in Hz (frequency of the wave supplied to the motor)
Regulation of the normal speed of the gate during the closing phase
NNN: speed expressed in Hz (frequency of the wave supplied to the motor)
Regulation of the speed of the gate during the closing phase when approaching the end of the run
NNN: speed expressed in Hz (frequency of the wave supplied to the motor)
Torque supplied to the motor during the opening phase at normal speed
NNN: percentage of torque supplied to the motor
Torque supplied to the motor during the opening phase when approaching the end of the run
NNN: percentage of torque supplied to the motor
Torque supplied to the motor during the closing phase at normal speed
NNN: percentage of torque supplied to the motor
Torque supplied to the motor during the closing phase when approaching the end of the run
NNN: percentage of torque supplied to the motor
EXIT
Select the language (where applicable)
Backlighting of the display
OFF: the light of the display is disabled
Backlight
ON: the light of the display is enabled and its automatic switching-off is timed (Energy saving)
Total reset of factory settings of the control board.
WARNING: all programming operations and the setting of the control board must be repeated after this
Reset
operation
EXIT
ITA
ENG
FRA
ESP
DEU
POR
7 / 12