Miele DA 200-2 Instrukcja obsługi i instalacji - Strona 32

Przeglądaj online lub pobierz pdf Instrukcja obsługi i instalacji dla Okap wentylacyjny Miele DA 200-2. Miele DA 200-2 36 stron. Cooker

Miele DA 200-2 Instrukcja obsługi i instalacji
All electrical work should be under-
taken by a suitably qualified and
competent person in strict accor-
dance with national and local safety
regulations.
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer can
not be held responsible for un-
authorised work.
Ensure power is not supplied to the
appliance while installation or repair
work is being carried out.
U.K., IRL, NZ, ZA: The cooker hood is
supplied for connection to an a.c.
230 V single phase 50 Hz supply.
AUS: The cooker hood is supplied for
connection to an a.c. single phase
240 V, 50 Hz supply.
The voltage, rated load and fusing are
given on the data plate. This is visible
when the grease filters have been re-
moved. Ensure that these match the
household mains supply.
For U.K.: Connection should be made
by a double pole fused spur connection
unit. The On-Off switch should be easily
accessible after the appliance has
been built in.
When switched off there must be an
all-pole contact gap of 3 mm in the
switch (including switch, fuses and re-
lays according to EN 60 335).
If the socket is not accessible after in-
stallation (depending on country) an
additional means of disconnection must
be provided for all poles.
32
For extra safety it is advisable to install a
residual current device (RCD) with a trip
current of 30 mA (in accordance with
DIN VDE 0664, VDE 0100 Section 739).
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue
= neutral
Brown
= live