Miele DA 249-2 EXT Instrukcja obsługi i instalacji - Strona 10

Przeglądaj online lub pobierz pdf Instrukcja obsługi i instalacji dla Okap wentylacyjny Miele DA 249-2 EXT. Miele DA 249-2 EXT 36 stron.

Miele DA 249-2 EXT Instrukcja obsługi i instalacji

Brief description

The cooker hood works with
. . . air extraction
The air is drawn in and cleaned by the
grease filters and then directed outside.
If the on-site ventilation system does
not have a non-return flap the
non-return flap supplied must be fit-
ted.
This flap is closed when the cooker
hood is switched off. No exchange of
room air and outside air can take place.
When the cooker hood is switched on,
the non-return flap opens for the cook-
ing smells to be blown directly outside.
10
. . . air recirculation
The air is drawn in and cleaned first by
the grease filter and then by an active
charcoal filter. The cleaned air is then
recirculated back into the kitchen
through vents in the top of the cooker
hood extension piece.
Before using the cooker hood for the
first time, ensure that the active
charcoal filter is in place, see sec-
tion on "Cleaning and care".
. . . an external fan
The EXT models are designed to be
connected to an external fan located
outside the room.
The external fan is connected to the
cooker hood by means of a control ca-
ble and is operated by the control
panel on the cooker hood.