Miele DA 429-4 EXT Instrukcja obsługi i instalacji - Strona 33
Przeglądaj online lub pobierz pdf Instrukcja obsługi i instalacji dla Okap wentylacyjny Miele DA 429-4 EXT. Miele DA 429-4 EXT 40 stron. Cooker
Również dla Miele DA 429-4 EXT: Instrukcja obsługi i instalacji (40 strony), Instrukcja obsługi i instalacji (40 strony)
Silencer
(optional accessory)
To achieve even further reductions in
noise levels, a special silencer can be
fitted in the ducting system.
Connection for air extraction
...with air extraction:
The silencer not only reduces noise
from the motor outside the house, but
also sounds from outside (e.g. traffic
noise).
For this reason the silencer must be
positioned as close as possible to the
ducting exit
...in recirculation mode:
The silencer needs to be positioned
between the exhaust connection and
the deflector
adequate space in the tower for fitting
it.
...air extraction with external motor:
To minimise noise from the motor in the
kitchen, the silencer should be
positioned in front of the external motor
if possible, or if the ducting is long,
above the exhaust connection on the
cooker hood
In the case of an external motor located
inside the house, fitting a silencer
behind the external motor
the noise of the motor outside the
house.
In all modes of operation, the most
effective noise reductions are
achieved if two silencers are fitted
one behind the other in the system.
.
. Ensure there is
.
reduces
33